- 14/11/11 - Catalog updated
- 17/9/08 - The new web site is online!
- The catalog was updated
read »
- Please surf our website thoroughly
read »
© Techno Fittings S.r.l. Company ISO 9001 certified
Certification number: 75176272157
Italian VAT no: IT 03745691000
For ultra clean technology.
Flow rate monitoring of pure water in wet stations for Semiconductor and Liquid crystal display production.
Suitable for the measurement and monitoring of various chemical liquid flows.
-
All PFA construction
- Output 4~20mA
- No Particle Generation / No moving Parts
- No dead Space
- Free Mounting Orientation
|
Measuring principle ![]() |
|
Model |
LK-P |
LK |
LK-S |
|
|
Type |
|
10A, 15A, 20A, 25A |
||
|
Fitting |
FINAL LOCK or tube fitting |
R 1/2 (only 10A) or union fitting |
||
|
Measurable Flow Range |
10A |
2.5 l/min ~ 20 l/min |
4 l/min ~ 25 l/min |
|
|
15A |
4 l/min ~ 40 l/min |
8 l/min ~ 50 l/min |
||
|
20A |
10 l/min ~ 90 l/min |
12 l/min ~ 80 l/min |
||
|
25A |
-------------------- |
20 l/min ~ 130 l/min |
||
|
Max Measurable Viscosity |
10A |
1.5mm2/sec |
2mm2/sec |
|
|
15A |
2.5mm2/sec |
3mm2/sec |
||
|
20A |
4mm2/sec |
4mm2/sec |
||
|
25A |
-------------------- |
5.5mm2/sec |
||
|
Accuracy |
within ±2%FS |
within ±2%FS |
within ±3%FS |
|
|
Max Working Pressure |
10A |
1MPa |
1MPa |
|
|
15A |
0.6MPa |
|||
|
20A |
0.5MPa |
|||
|
Wetted Material |
PFA |
Linear PPS |
||
|
Liquid Temperature |
0~90°C |
|||
|
Ambient Temperature |
0~50°C |
0~0°C |
-10~70°C |
|
|
Preservation Temperature |
-10~60°C |
-20~70°C |
||
|
Power Supply |
DC 12~24V ±10% |
DC 3V (AAA battery x 2 pcs) |
DC 17~25 V max load resistance 50 W (at 17V) |
|
|
Display Part |
*1 |
*2 |
N/A |
|
|
Output Signal |
Flow rate : 4~20mA alarm : open connector |
N/A |
Flow rate : 4~20mA |
|
|
Sampling Time |
3 sec |
|||
|
Installation |
Can be mounted in any position provided that the LED display is adjusted correctly |
|||
« Back


